Tracing kits for chillers and air conditioning

Tracing kits for chillers and air conditioning

Leaks in refrigeration circuits can be difficult to locate, particularly when they are slow, intermittent or situated in an area that is difficult to access. Fluotechnik tracing kits bring together the products and accessories needed to prepare the inspection, introduce the tracer and examine suspected areas more accurately. Designed for refrigeration technicians, air-conditioning specialists and HVAC maintenance professionals, they can be used on chillers, air-conditioning systems, refrigeration installations and technical cooling equipment. Depending on their contents, the kits may combine a tracer, application equipment, dosing accessories and detection tools, providing a consistent solution that is ready for use in the field.

A solution ready for field use

Find the products and equipment required to apply the tracer and inspect the circuit in a single kit.

Designed for refrigeration professionals

Work on chillers, air-conditioning systems, refrigeration circuits and HVAC installations.

More targeted leak detection

The tracer helps locate areas of seepage or fluid loss that may otherwise be difficult to identify.

Different equipment levels available

Choose a kit suited to occasional inspections, regular maintenance or the complete equipment of a technician.

Expert technical support

Fluotechnik helps you select a solution compatible with your installation, protocol and frequency of use.

A solution ready for field use

Find the products and equipment required to apply the tracer and inspect the circuit in a single kit.

Designed for refrigeration professionals

Work on chillers, air-conditioning systems, refrigeration circuits and HVAC installations.

More targeted leak detection

The tracer helps locate areas of seepage or fluid loss that may otherwise be difficult to identify.

Different equipment levels available

Choose a kit suited to occasional inspections, regular maintenance or the complete equipment of a technician.

Expert technical support

Fluotechnik helps you select a solution compatible with your installation, protocol and frequency of use.

Our tracing kits for refrigeration and air-conditioning circuits

Fluotechnik offers several kit configurations for diagnosing chillers, air-conditioning systems, HVAC equipment and other refrigeration installations. Bringing these components together makes it possible to prepare the operation with the appropriate equipment without having to select each item separately. The choice of kit depends on the type of installation, the refrigerants and lubricants involved, the number of inspections carried out and the equipment already available.

Depending on the product, kits may include:

  • One or more suitable tracers
  • Injection or application accessories
  • Dosing equipment
  • A UV lamp or other detection equipment
  • Glasses designed to improve signal contrast
  • Storage or transport accessories

What is a leak detection kit for air conditioning and chillers used for?

A tracing kit helps locate the source of a leak more accurately within a refrigeration installation. A compatible tracer is introduced into the circuit according to the appropriate procedure and then circulates with the fluid or lubricant. If a leak is present, the tracer may appear around the affected area and can be identified using suitable detection equipment.

This method can make it easier to inspect:

  • Fittings and connections
  • Hoses and pipes
  • Valves
  • Heat exchangers
  • Compressors
  • Areas that have previously been repaired
  • Components that are difficult to inspect directly

The value of a kit lies in the complementary nature of its components. The technician has access not only to the tracer but also to the accessories required to apply it, measure the correct quantity and reveal its signal. For professionals who already have a lamp and the necessary application equipment, purchasing a UV tracer alone may be sufficient. A kit is more appropriate when a complete set is needed or when several pieces of equipment must be replaced at the same time.

How do you use a tracing kit on a refrigeration circuit?

The method depends on the contents of the kit, the installation being inspected and the instructions provided for the tracer. Before beginning any operation, it is essential to check that the products are compatible with the refrigerant, lubricant and circuit components.

Step 1 - Identify the installation and circuit concerned

Begin by determining the type of equipment:

  • Chiller
  • Air-conditioning system
  • HVAC installation
  • Refrigeration circuit
  • Cold room
  • Technical cooling equipment

The characteristics of the installation help determine the appropriate tracer, application method and accessories.

Step 2 - Define the purpose of the inspection

The kit can be used in several situations:

  • Locating a leak that is difficult to identify;
  • Inspecting a suspected area;
  • Checking the installation after a repair;
  • Carrying out diagnostics during maintenance;
  • Monitoring an installation showing gradual fluid loss.

The purpose of the inspection determines the examination method and when the circuit should be checked.

Step 3 - Check the tracer’s compatibility

Before application, ensure that the tracer is suitable for the circuit, refrigerant, lubricant and operating procedure. The quantity used and the method of introduction must comply with the product recommendations. Correct dosing produces a usable signal without introducing an unnecessary amount into the installation.

Step 4 - Introduce the tracer into the circuit

The product is applied using the accessories supplied in the kit or compatible equipment. This operation must be carried out by a qualified professional in accordance with the procedures applicable to the installation. The system is then operated under the conditions required for the tracer to circulate towards any potential leak.

Step 5 - Inspect areas likely to leak

When the kit uses a fluorescent tracer, the inspection is carried out with a suitable UV lamp. Fittings, valves, pipes, heat exchangers and other sensitive points are examined systematically. Contrast glasses or filters can improve signal visibility and make faint traces easier to identify.

Step 6 - Confirm the leak and prepare the repair

A signal appearing in a specific area helps target the intervention. The technician can then confirm the diagnosis, clean the area where necessary and prepare the repair or replacement of the affected component. A further inspection can be carried out after the work to check the result.

Why choose a Fluotechnik kit for refrigeration and air-conditioning diagnostics?

Effective leak detection depends both on selecting the right tracer and on using suitable equipment to apply and observe it. Fluotechnik kits are designed to bring together complementary components and make work on refrigeration installations easier to organise.

A consistent diagnostic setup

The different components are brought together to prepare the application, introduce the tracer and inspect suspected areas.

Time saved in the field

Technicians have the accessories they need from the beginning of the operation, reducing forgotten equipment and time spent searching for tools.

Solutions for several types of installation

The kits can meet the requirements of chillers, air-conditioning systems, HVAC installations and other compatible refrigeration circuits.

Accurate detection under UV light

When a leak is marked by a fluorescent tracer, the lamp and detection accessories make the signal easier to locate.

Different kit configurations available

Select a kit according to your existing equipment, the frequency of your inspections and the accessories you genuinely need.

Expert technical support

Our team helps you identify the kit suited to your installations, application method and working conditions.

FAQ about kits for chillers and air conditioning

It is a set of products and equipment designed to make leak detection easier within a refrigeration circuit. Depending on its contents, the kit may include a tracer, application accessories, dosing equipment, a UV lamp, contrast glasses or other useful diagnostic tools.

The UV tracer is the fluorescent product introduced into the circuit. The kit combines this product with some or all of the equipment required to apply it and observe its signal. A tracer alone may suit a technician who already has the necessary equipment. A kit is more suitable when a complete solution is required.

A kit is particularly useful for:

  • Equipping a technician or team
  • Starting to use fluorescent tracer detection
  • Replacing several accessories
  • Carrying out diagnostics regularly
  • Having organised, portable equipment

Depending on the products they contain, the kits may be used on chillers, air-conditioning systems, HVAC installations, cold rooms, refrigeration circuits and other technical cooling equipment. Compatibility with the installation, refrigerant and lubricant must always be checked.

A fluorescent tracer can help locate many leaks, but the result depends on factors such as their position, size, circulation time and the accessibility of the affected area. The method may need to be combined with other diagnostic techniques when conditions require it.

A UV lamp is required when detection relies on a fluorescent tracer that is invisible or difficult to see under ordinary lighting. Some kits include a lamp and contrast accessories.

The required time depends on the installation, circulation rate, location of the leak and procedure used. Some leaks can be identified quickly, while others require the tracer to circulate for longer.

No. The tracer must be compatible with the refrigerant, lubricant, circuit materials and the equipment manufacturer’s recommendations.

The choice depends on:

  • The type of installation
  • The refrigerants and lubricants involved
  • Your existing equipment
  • Yhe number of planned operations
  • The required application method
  • The preferred lamp power and format

Fluotechnik can help you compare the available configurations.

Choosing a kit suited to your refrigeration operations

For refrigeration and HVAC technicians, having the right equipment makes it possible to prepare leak detection operations more quickly and inspect installations under better conditions.

The choice of kit mainly depends on:

  • The type of equipment: chiller, air-conditioning system, cold room, refrigeration circuit or HVAC installation
  • The refrigerants and lubricants present in the circuit; the compatible tracer type
  • The required application method
  • The equipment already available
  • The frequency of inspections
  • Inspection and accessibility conditions
  • The required detection sensitivity

A professional who already has a UV lamp and injection accessories may prefer to purchase the tracer alone. A complete kit, by contrast, makes it easier to implement a consistent method by combining the product, application equipment and detection tools. Some configurations are suitable for occasional use, while others better meet the requirements of technicians carrying out regular maintenance and leak detection operations. Fluotechnik supports you in selecting a solution compatible with your installations and field operations.

Complete your equipment for refrigeration system diagnostics

Complete kit, UV tracer, lamp or solution intended for another type of circuit: discover the Fluotechnik ranges that allow you to adapt your equipment to the installations and fluids you work with.

Tracing in industrial environments

Discover our solutions for inspecting fluids, circuits and industrial installations.
Tracing in industrial environments
Explore Fluotechnik applications for oils and fuels, chillers, cooling circuits, filtration, water, safety and contamination.
SEE PRODUCTS

UV tracers for air conditioning and chillers

Choose the fluorescent product suited to your circuit and application method.
UV tracers for air conditioning and chillers
Already have the required injection and detection equipment? Explore the UV tracers available separately for work on refrigeration installations.
SEE PRODUCTS

Kits for oils and fuels

Equip your diagnostic operations on oil, fuel and hydrocarbon-based fluid circuits.
Kits for oils and fuels
These kits bring together the products and accessories needed to locate leaks or monitor fluid circulation in installations using oils or fuels.
SEE PRODUCTS

Water tracing kits

Carry out tracing operations on networks, pipelines and installations using water.
Water tracing kits
Discover kits suited to flow monitoring, connection checks and diagnostics on water and sanitation networks.
SEE PRODUCTS

Fluorescent UV markers

Reveal passages, leaks or contamination that are difficult to observe directly.
Fluorescent UV markers
Discover our fluorescent markers for industrial applications requiring sensitive detection and observation under a UV lamp.
SEE PRODUCTS